본문
| Model | BS-AHIDC |
|---|---|
| Used | Connecting HID(high intensity discharge) head lamp in vehicle with HID AHLS (Auto Headlamp Leveling System) |
| Structure | ① Conductor ② Insulation ③ Taping ④ Shield ⑤ Jacket |
Securing visual range by auto-controlling the intensity of illumination and the glancing angle to improve driving safety
Description
- Silicone rubber composite cable with excellent heat resistance and flexibility
- Excellent for internal wiring of lamps and lighting equipment
Rating
- Temperature range : -60℃~200℃
- Voltage : 300V/ 600V
- Passing grade test for fire retardant, mechanical strength, and electrical characteristics according to UL standard
Property
- Excellent excess moisture, UV ultraviolet resistance, and ozone resistance for both high and low temperature environments
- Easy to connect devices in narrow and high temperatures with great flexibility
- Through multiple cladding structural design, shock resistance are excellent
C-UL Certification Approved
- File No. : E131290
- Reference : UL 758, 1581
| Style No. | Rating | AWG No. | Insulation Thickness (mm) | |
|---|---|---|---|---|
| Volt.(V) | Temp.(℃) | |||
| 3977 | 300 | 200 | 0.05~250SQ | 0.38 |
| 3978 | 600 | 200 | 0.05~250SQ | 0.76 |
![]()